Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Model
|
Rated Voltage
|
Insulation Resistance Range
|
Short Circuit Current
|
9600
|
250V,500V,1KV,2.5KV,5KV
|
0.50MΩ~2.00TΩ
|
>5mA
|
9600B
|
250V,500V,1KV,2.5KV,5KV,10KV
|
0.50MΩ~5.00TΩ
|
>5mA
|
1. Insulation Resistance Range and Accuracy
|
||
Rated Voltage
|
Insulation Resistance Range
|
Accuracy
|
250V
|
0.50MΩ~10.0GΩ
|
±5%±3dgt
|
10.0GΩ~50.0GΩ
|
±10%±3dgt
|
|
50.0GΩ~100GΩ
|
±20%±3dgt
|
|
|
1.00MΩ~20.0GΩ
|
±5%±3dgt
|
20.0GΩ~100GΩ
|
±10%±3dgt
|
|
100GΩ~200GΩ
|
±20%±3dgt
|
|
|
1.00MΩ~50.0GΩ
|
±5%±3dgt
|
50.0GΩ~200GΩ
|
±10%±3dgt
|
|
200GΩ~500Ω
|
±20%±3dgt
|
|
|
1.00MΩ~100GΩ
|
±5%±3dgt
|
100GΩ~500GΩ
|
±10%±3dgt
|
|
500GΩ~1.00TΩ
|
±20%±3dgt
|
|
|
1.00MΩ~200GΩ
|
±5%±3dgt
|
200GΩ~1.00TΩ
|
±10%±3dgt
|
|
1.00TΩ~2.00TΩ
|
±20%±3dgt
|
|
|
1.00MΩ~500GΩ
|
±5%±3dgt
|
500GΩ~2.00TΩ
|
±10%±3dgt
|
|
2.00TΩ~5.00TΩ
|
±20%±3dgt
|
Function
|
Insulation resistance measurement (IR); polarization index measurement (PI); absorption ratio (DAR); filtered resistance test ( four time selection 10S,20S,30S,40S) Voltage measurement(V); Leakage current measurement(nA) |
Power Supply
|
Rechargeable lithium battery 5.2Ah
|
Rated Voltage
|
9600:250V,500V,1KV,2.5KV,5KV 9600B:250V,500V,1KV,2.5KV,5KV,10KV |
Output Voltage Accuracy
|
(5%~10%)±10V
|
Insulation Resistance Test Range
|
9600:0.50MΩ~2.00TΩ 9600B:0.50MΩ~5.00TΩ |
Output Short Circuit Current
|
>5mA
|
Polarization Index Test
|
YES
|
Dielectric Absorption Ratio Test
|
YES
|
Ramp Test Mode
|
Step up to the preset voltage by testing with 10% stepped size of the preset voltage.
|
Filtered Resistance Test Mode
|
10S,20S,30S,40S four selections
|
Voltage Test
|
Range:AC/DC:0V~1000V;Accuracy: ±5%rdg±3V
|
Current Test
|
Range:0.01nA~5mA;Accuracy: ±5%rdg±0.5nA
|
Voltage Monitor
|
Monitor the voltage of the measured object, and monitor discharge status after test, forbidden to test when voltage exceed 36V, protect instrument and operator. |
Test Timer
|
Automatic record test time, time range: 0s~9999s
|
Storage Function
|
Automatically store the test data with test date and time, total of 1000 groups
|
Upload Function
|
Upload the stored data to computer via USB communication cable.
|
Battery Power Display
|
With battery power display, when battery voltage low will remind to replace the battery
|
Automatic Shutdown
|
After 15 minutes start up will shut down automatically without any operation
|
Meter Dimension
|
280mm×260mm×160mm
|
Meter Weight
|
4400g (include the battery)
|
Test Wires
|
Red color high voltage test wire 1 pcs (with alligator clip 1PCS and hook 1PCS), green color test wire 1PCS, black color test wire 1PCS |
Protection Level
|
Close the case IP65, open the case IP40
|
Working Environment
|
-20ºC~50ºC;80%rh
|
Store Environment
|
-25ºC~65ºC;80%rh
|
Insulation Resistance
|
50MΩ(1000v)(between the test circuit and shell)
|
Withstand Voltage
|
AC 3Kv 50Hz 1min(between the test circuit and shell)
|
Suitable Safety Standard
|
IEC61010-1,IEC61326-1
|